RDR5 seriyali termal o'rni (o'rni) asosan AC50 / 60Hz pallasida qo'llaniladi, nominal ish kuchlanishi 690V gacha, nominal impulsga chidamli kuchlanish

Uimp (kv): 8, Nominal oqim 0,1-93 (A), uzoq muddatli ish yoki uzilish sifatida uzoq muddatli kontaktlarning zanglashiga olib, dvigatelning haddan tashqari yuklanishini buzish, himoya qilish.

Standart: IEC 60947-4-1 GB14048.4


  • RDR5 seriyali termal o'rni 0,1 ~ 93A - RDC5 maxsus o'rni

Mahsulot detali

Ilova

Parametrlar

Namunalar va tuzilmalar

O'lchamlari

Mahsulot taqdimoti

RDR5 seriyali termal o'rni (o'rni) asosan AC50 / 60Hz pallasida qo'llaniladi, nominal ish kuchlanishi 690V gacha, nominal impulsga chidamli kuchlanish

Uimp (kv): 8, Nominal oqim 0,1-93 (A), uzoq muddatli ish yoki uzilish sifatida uzoq muddatli kontaktlarning zanglashiga olib, dvigatelning haddan tashqari yuklanishini buzish, himoya qilish.

Standart: IEC 60947-4-1 GB14048.4

46

Model raqami Ramka o'lchami O'rnatish oqimi Model raqami Ramka o'lchami O'rnatish oqimi
RDR5-25 25 0,1-0,16A
0,13-0,25A
0,25-0,4A
0,4-0,63A
0,63A-1A
1-1,6A
1,25-2A
2,5-4A
4-6A
5,5-8A
7-10A
9-13A
12-18A
17-25A
RDR5-36 36 23-32A
28-36A
RDR5-93 93 23-32A
30-40A
37-50A
48-65A
55-70A
63-80A
80-93A
  RDA5-25 RDR5-36 RDR5-93
Joriy daraja 25 36 93
Nominal izolyatsiya kuchlanish Ui (V) 690 690 690
Fazali yo'qotishdan himoya qilish Ha Ha Ha
Qo'lda va avtomatik tiklash Ha Ha Ha
Harorat kompensatsiyasi Ha Ha Ha
O'chirish induktori Ha Ha Ha
Sinov tugmasi Ha Ha Ha
To'xtatish tugmasi Ha Ha Ha
O'rnatish turi Kiritish turi Kiritish turi Kiritish turi
Yordamchi aloqa 1NO+1NC 1NO+1NC 1NO+1NC
AC-15 220V Nominal tok A 2.7 2.7 2.7
AC-15 380V Nominal tok A 1.5 1.5 1.5
DC-13 220V Nominal oqim A 0,2 0,2 02
Mos keladigan kontaktor RDC5-06.09,12,18,25.38 RDC5-32,38 RDC5-40,50,65,80,95
Nominal impulsga chidamli kuchlanishUimp 8kV
Standart G814048.4 IEC60947-4-1

 

RDR5 (2) RDR5 (3)

Shakl va o'rnatish o'lchamlari

47

46

Model raqami Ramka o'lchami O'rnatish oqimi Model raqami Ramka o'lchami O'rnatish oqimi
RDR5-25 25 0,1-0,16A
0,13-0,25A
0,25-0,4A
0,4-0,63A
0,63A-1A
1-1,6A
1,25-2A
2,5-4A
4-6A
5,5-8A
7-10A
9-13A
12-18A
17-25A
RDR5-36 36 23-32A
28-36A
RDR5-93 93 23-32A
30-40A
37-50A
48-65A
55-70A
63-80A
80-93A
  RDA5-25 RDR5-36 RDR5-93
Joriy daraja 25 36 93
Nominal izolyatsiya kuchlanish Ui (V) 690 690 690
Fazali yo'qotishdan himoya qilish Ha Ha Ha
Qo'lda va avtomatik tiklash Ha Ha Ha
Harorat kompensatsiyasi Ha Ha Ha
O'chirish induktori Ha Ha Ha
Sinov tugmasi Ha Ha Ha
To'xtatish tugmasi Ha Ha Ha
O'rnatish turi Kiritish turi Kiritish turi Kiritish turi
Yordamchi aloqa 1NO+1NC 1NO+1NC 1NO+1NC
AC-15 220V Nominal tok A 2.7 2.7 2.7
AC-15 380V Nominal tok A 1.5 1.5 1.5
DC-13 220V Nominal oqim A 0,2 0,2 02
Mos keladigan kontaktor RDC5-06.09,12,18,25.38 RDC5-32,38 RDC5-40,50,65,80,95
Nominal impulsga chidamli kuchlanishUimp 8kV
Standart G814048.4 IEC60947-4-1

 

RDR5 (2) RDR5 (3)

Shakl va o'rnatish o'lchamlari

47

Xabaringizni shu yerga yozing va bizga yuboring